12 leads if leads are numbered 1 to 12 the motor is typically rated for two voltages and could be used with a wye delta starter at either voltage or a part winding starter for low voltage only. 12 leads terminal wiring guide for dual voltage delta connected ac induction motor the previous article presented the terminal wiring connection for a 12 leads star wye configured induction motor.
The 12 lead motor is a very versatile motor and can be connected in numerous ways.
You can find out more Diagram below
12 lead motor. It reveals the elements of the circuit as simplified shapes as well as the power and also signal connections in between the tools. Another type of 12 leads wiring configuration which is a distinguished counterpart to the star wye motor connection is the delta configuration. Across the line starting on the delta run connection where the full winding is energized at either high or low voltage.
Wye startdelta run initially the motor will start monetarily on the wye connection and then switch to. The 12 lead motor is a very versatile motor and can be connected in numerous ways. A 12 lead wye startdelta run motor has the ability to meet several starting criteria such as.
It is a dual speed motor and can be wired as star delta. Assortment of weg 12 lead motor wiring diagram. Electrical motors 12 lead dual voltage wye startdelta run both voltages or 6 lead single voltage wye startdelta run motors designed by us motors for wye start delta run may also be used for across the line starting using only the delta connection.
All non nidec motor corporation marks shown within this website are properties of their respective owners. It is a dual speed motor and can be wired as star delta. A wiring diagram is a streamlined standard photographic depiction of an electric circuit.
Damage will occur if the motor is operated with load for more than 30 seconds on the wye without transition to delta. Patent and trademark office. Units rated for single voltage may have 12 leads and be suitable for wye delta or part winding starts.
Three phase wiring diagrams always use wiring diagram supplied on motor nameplate colored leads are only applicable on the new rolled steel motor lines single phase wiring diagrams always use wiring diagram supplied on motor nameplate for motors with thermal protection single voltage single rotation single voltage reversible rotation. Nidec motor corporation trademarks followed by the symbol are registered with the us.